Awilco multiplex IP-EFOY-GATEWAY Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405
mail@awilco-multiplex.dk | www.awilco-multiplex.dk
List of tables
Table 1: Electrical Data ....................................................................................................................................... 6
Table 2: Mechanical Data ................................................................................................................................... 6
Table 3: Environment conditions ....................................................................................................................... 6
Table 4: IP default settings ................................................................................................................................. 7
Table 5: Description front panel ........................................................................................................................ 8
Table 6: Description front panel ........................................................................................................................ 9
Table 7: TCP/UDP Protocols ............................................................................................................................. 10
Table 8: Protocol RS232 ................................................................................................................................... 10
Table 9: EFOY PRO compatibility ...................................................................................................................... 10
Table 10: Description web site - General ......................................................................................................... 17
Table 11: Description web site - IP ................................................................................................................... 18
Table 12: Description web site - Security ......................................................................................................... 19
Table 13: Description web site SNMP ........................................................................................................... 20
Table 14: Description web site - EFOY Supervisor ............................................................................................ 22
Table 15: Description web site - EFOY Setup ................................................................................................... 24
Table 16: Description web site - EFOY Status ................................................................................................... 25
Table 17: Description web site - EFOY Errors ................................................................................................... 27
Table 18: Description web site - Info ................................................................................................................ 29
Table 19: Notification event ............................................................................................................................. 30
Table 20: Configuration fields Email notification ............................................................................................. 31
Table 21: Description event protocol ............................................................................................................... 32
1 Introduction
The IP-EFOY-GATEWAY serves for remote control of a single SFC EFOY PRO fuel cell over the TCP/IP protocol.
At this the entire fuel cell parameter defined by the SFC EFOY PRO technical data sheet are readout continu-
ously over the RS232 interface. These data sets are provided to the customer for control application in dif-
ferent formats.
SNMP
XML
HTML web site
Email
TCP-UART-Bridge-Mode (direct EFOY Pro remote command line interface terminal)
TCP socket services can be developed on request
Furthermore, the IP-EFOY-GATEWAY gives the customer the opportunity to set up/reconfigure the EFOY PRO
fuel cell either within a local area network or over the internet by using the web site. There is no need for
further software installation.
The customer benefits from a simple and intuitive web menu navigation to preconfigure the fuel cell ex ante
or in a live running system.
However, the greatest benefit of the IP-EFOY-GATEWAY solution is that it makes it possible to give your
EFOY PRO fuel cell an IP address and that it can be integrated in a given IP network very quickly without any
limitations. From now on statically scheduled service tours are minimized and can be coordinated much
better since EFOY PRO fuel cell's parameter/states may be retrieved from each location and 24 hours a day.